{"title":"SBIG Adaptive Optics","description":"\u003cp\u003eSBIG Adaptive Optics. Part of \u003ca href=\"\/collections\/diffraction-limited\"\u003eDiffraction Limited\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"ao-8a-adaptive-optics-unit-for-aluma-cameras","title":"AO-8A -Adaptive Optics unit for Aluma cameras","description":"\u003cp style=\"box-sizing: inherit; margin: 1.625rem 0px; font-size: 1.125rem; line-height: 1.888; color: rgb(98, 98, 98); font-family: Lato, Helvetica, Arial, sans-serif; background-color: rgb(255, 255, 255);\"\u003eThe AO-8A is designed for the Aluma Camera Series.\u003c\/p\u003e\u003cp style=\"box-sizing: inherit; margin: 1.625rem 0px; font-size: 1.125rem; line-height: 1.888; color: rgb(98, 98, 98); font-family: Lato, Helvetica, Arial, sans-serif; background-color: rgb(255, 255, 255);\"\u003eThe AO-8A requires an off-axis guide camera behind the device.  We recommend using the FW8G-Aluma filter wheel.  The AO-8A can also be used with a Remote Guide Head if you have a custom Off-Axis Guider.\u003c\/p\u003e\u003ch3 style=\"box-sizing: inherit; margin: 2rem 0px 1rem; font-family: Lato, Helvetica, Arial, sans-serif; font-weight: 300; line-height: 1.2; font-size: 1.8rem; color: rgb(34, 39, 58); background-color: rgb(255, 255, 255); text-align: center;\"\u003eAO Results\u003c\/h3\u003e\u003cp style=\"box-sizing: inherit; margin: 1.625rem 0px; font-size: 1.125rem; line-height: 1.888; color: rgb(98, 98, 98); font-family: Lato, Helvetica, Arial, sans-serif; background-color: rgb(255, 255, 255);\"\u003eThe images below are actual star images showing the effect of image wander corrected at 1 Hz and 10 Hz:\u003c\/p\u003e\u003cp style=\"box-sizing: inherit; margin: 1.625rem 0px; font-size: 1.125rem; line-height: 1.888; color: rgb(98, 98, 98); font-family: Lato, Helvetica, Arial, sans-serif; background-color: rgb(255, 255, 255); text-align: center;\"\u003e\u003cimg class=\"aligncenter wp-image-1834 size-full\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/ao_mov_1hz_5c1ba072-687f-4c7f-a8da-d827366b8ab7.gif?v=1766555224\" alt=\"ao_mov_1hz\" width=\"200\" height=\"200\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/ao_mov_1hz_5c1ba072-687f-4c7f-a8da-d827366b8ab7.gif?v=1766555224 200w, http:\/\/diffractionlimited.com\/wp-content\/uploads\/2016\/11\/ao_mov_1hz-120x120.gif 120w, http:\/\/diffractionlimited.com\/wp-content\/uploads\/2016\/11\/ao_mov_1hz-180x180.gif 180w\" sizes=\"(max-width: 200px) 100vw, 200px\" style=\"box-sizing: inherit; margin: 1rem auto; border: 0px; vertical-align: middle; max-height: 100vh; display: block; max-width: 100%; height: auto;\"\u003e1 Hz Corrections\u003c\/p\u003e\u003cp style=\"box-sizing: inherit; margin: 1.625rem 0px; font-size: 1.125rem; line-height: 1.888; color: rgb(98, 98, 98); font-family: Lato, Helvetica, Arial, sans-serif; background-color: rgb(255, 255, 255); text-align: center;\"\u003e\u003cimg class=\"aligncenter wp-image-1825 size-full\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/ao_mov_10hz_f9d0fb93-8746-44e1-a5b3-805ee6154d42.gif?v=1766555226\" alt=\"ao_mov_10hz\" width=\"200\" height=\"200\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/ao_mov_10hz_f9d0fb93-8746-44e1-a5b3-805ee6154d42.gif?v=1766555226 200w, http:\/\/diffractionlimited.com\/wp-content\/uploads\/2016\/11\/ao_mov_10hz-120x120.gif 120w, http:\/\/diffractionlimited.com\/wp-content\/uploads\/2016\/11\/ao_mov_10hz-180x180.gif 180w\" sizes=\"(max-width: 200px) 100vw, 200px\" style=\"box-sizing: inherit; margin: 1rem auto; border: 0px; vertical-align: middle; max-height: 100vh; display: block; max-width: 100%; height: auto;\"\u003e\u003cbr style=\"box-sizing: inherit; margin: 0px;\"\u003e10 Hz Corrections\u003c\/p\u003e\u003cp style=\"box-sizing: inherit; margin: 1.625rem 0px; font-size: 1.125rem; line-height: 1.888; color: rgb(98, 98, 98); font-family: Lato, Helvetica, Arial, sans-serif; background-color: rgb(255, 255, 255); text-align: center;\"\u003eAnd the resulting size of the star image in a long exposure:\u003c\/p\u003e\u003cp style=\"box-sizing: inherit; margin: 1.625rem 0px; font-size: 1.125rem; line-height: 1.888; color: rgb(98, 98, 98); font-family: Lato, Helvetica, Arial, sans-serif; background-color: rgb(255, 255, 255); text-align: center;\"\u003e\u003cimg class=\"aligncenter\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/aox-1hz-corrected-250x250_9163ce19-0469-4294-b785-4f60d4d1572a.png?v=1766555227\" alt=\"aox-1hz-corrected\" width=\"250\" height=\"250\" style=\"box-sizing: inherit; margin: 1rem auto; border: 0px; vertical-align: middle; max-height: 100vh; display: block; max-width: 100%; height: auto;\"\u003e\u003cbr style=\"box-sizing: inherit; margin: 0px;\"\u003e1 Hz Corrections\u003c\/p\u003e\u003cp style=\"box-sizing: inherit; margin: 1.625rem 0px; font-size: 1.125rem; line-height: 1.888; color: rgb(98, 98, 98); font-family: Lato, Helvetica, Arial, sans-serif; background-color: rgb(255, 255, 255);\"\u003e\u003cimg class=\"aligncenter\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/aox-10hz-corrected-250x250_bc36067b-1e84-4ff8-9e1d-f152fa518935.png?v=1766555229\" alt=\"aox-10hz-corrected\" width=\"250\" height=\"250\" style=\"box-sizing: inherit; margin: 1rem auto; border: 0px; vertical-align: middle; max-height: 100vh; display: block; max-width: 100%; height: auto;\"\u003e\u003cbr style=\"box-sizing: inherit; margin: 0px;\"\u003e10 Hz Corrections\u003c\/p\u003e\u003cp style=\"box-sizing: inherit; margin: 1.625rem 0px; font-size: 1.125rem; line-height: 1.888; color: rgb(98, 98, 98); font-family: Lato, Helvetica, Arial, sans-serif; background-color: rgb(255, 255, 255); text-align: center;\"\u003eOther data gathered by Brad Wallis of JPL (Brad Wallis and Benoit Schillings developed the prototype for the original AO-7) show the the effect of rapid corrections on poor seeing.  At 1 Hz the larger, slower component is reduced, but the amplitude of the jitter remains about the same:\u003c\/p\u003e","brand":"SBIG","offers":[{"title":"Default Title","offer_id":44013533069423,"sku":"AO-8A","price":1369.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/ao8__61374.jpg?v=1766555231"},{"product_id":"sbig-ao-8a-adaptive-optics","title":"SBIG AO-8A Adaptive Optics","description":"\u003cp\u003eThe SBIG AO-8A improves image quality through rapid, precise guiding corrections.  It can correct star motion 10 times per second, which can mitigate slow seeing as well as wind gusts, tracking errors, and other guiding issues.\u003c\/p\u003e\n\u003cp\u003eAO-8A works with STC and Aluma CCD cameras in conjunction with the\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/ontariotelescope.com\/products\/sbig-starchaser-sc-4-off-axis-guider-camera\" target=\"_blank\"\u003eStarChaser SC-4C\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eautoguider.  It can also work with our legacy cameras with FW8G-Aluma or FW8G-STT self-guided filter wheels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen using\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/ontariotelescope.com\/products\/sbig-starchaser-sc-4-off-axis-guider-camera\" target=\"_blank\"\u003eStarChaser SC-4C\u003cspan\u003e \u003c\/span\u003e\u003c\/a\u003ewith AO, you will need a\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/ontariotelescope.com\/products\/starchaser-aluma-ccd-stc-to-db9-adapter-cables\" target=\"_blank\"\u003eStarChaser to AO-X\/AO-8T Adapter Cable.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eAO Results\u003c\/h3\u003e\n\u003cp\u003eThe images below are actual star images showing the effect of image wander corrected at 1 Hz and 10 Hz:\u003c\/p\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1834 size-full\" src=\"https:\/\/diffractionlimited.com\/wp-content\/uploads\/2024\/02\/ao_mov_1hz.gif\" alt=\"ao_mov_1hz\" width=\"200\" height=\"200\"\u003e1 Hz Corrections\u003c\/p\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1825 size-full\" src=\"https:\/\/diffractionlimited.com\/wp-content\/uploads\/2024\/02\/ao_mov_10hz.gif\" alt=\"ao_mov_10hz\" width=\"200\" height=\"200\"\u003e10 Hz Corrections\u003c\/p\u003e\n\u003cp\u003eAnd the resulting size of the star image in a long exposure:\u003c\/p\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/diffractionlimited.com\/wp-content\/uploads\/2016\/04\/aox-1hz-corrected-250x250.png\" alt=\"aox-1hz-corrected\" width=\"250\" height=\"250\"\u003e1 Hz Corrections\u003c\/p\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/diffractionlimited.com\/wp-content\/uploads\/2016\/04\/aox-10hz-corrected-250x250.png\" alt=\"aox-10hz-corrected\" width=\"250\" height=\"250\"\u003e10 Hz Corrections\u003c\/p\u003e\n\u003cp\u003eOther data gathered by Brad Wallis of JPL (Brad Wallis and Benoit Schillings developed the prototype for the original AO-7) show the the effect of rapid corrections on poor seeing.  At 1 Hz the larger, slower component is reduced, but the amplitude of the jitter remains about the same:\u003c\/p\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1832 size-full\" src=\"https:\/\/diffractionlimited.com\/wp-content\/uploads\/2024\/02\/ao_1hz.gif\" alt=\"ao_1hz\" width=\"959\" height=\"719\"\u003e\u003c\/p\u003e\n\u003cp\u003eHowever, at a 5Hz correction rate, the faster jitter is reduced:\u003c\/p\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1831 size-full\" src=\"https:\/\/diffractionlimited.com\/wp-content\/uploads\/2024\/02\/ao_5hz.gif\" alt=\"ao_5hz\" width=\"959\" height=\"719\"\u003e\u003c\/p\u003e\n\u003cp\u003eAnd at a 10 Hz correction rate, significant improvement is seen:\u003c\/p\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1830 size-full\" src=\"https:\/\/diffractionlimited.com\/wp-content\/uploads\/2024\/02\/ao_10hz.gif\" alt=\"ao_10hz\" width=\"959\" height=\"719\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe improvement in stellar profiles can also be seen at corrections above 1 Hz.  First by looking at the non-AO guided image:\u003c\/p\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1829 size-full\" src=\"https:\/\/diffractionlimited.com\/wp-content\/uploads\/2024\/02\/aox_img2.jpg\" alt=\"aox_img2\" width=\"687\" height=\"680\"\u003e\u003c\/p\u003e\n\u003cp\u003eAnd comparing the non-AO guided image to the AO guided image there is again significant improvement in the FWHM of the star profile:\u003c\/p\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1828 size-full\" src=\"https:\/\/diffractionlimited.com\/wp-content\/uploads\/2024\/02\/ao_img2.jpg\" alt=\"ao_img2\" width=\"720\" height=\"568\"\u003e\u003c\/p\u003e\n\u003cp\u003eTelescope mounts cannot correct faster than about once per second.  The 10Hz rate of the AO will clearly result in improved resolution under the right conditions.\u003c\/p\u003e","brand":"Diffraction Limited","offers":[{"title":"ALUMA CCD\/STF SERIES","offer_id":44013932642415,"sku":"AO-8T","price":1348.65,"currency_code":"CAD","in_stock":true},{"title":"STT SERIES","offer_id":44013932675183,"sku":"AO-8T","price":1348.65,"currency_code":"CAD","in_stock":true},{"title":"ST-7 SERIES","offer_id":44013932707951,"sku":"AO-8T","price":1348.65,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/Diffraction-AO-8A-.003-600x600__52590.jpg?v=1766567132"},{"product_id":"sbig-ao-x-adaptive-optics","title":"SBIG AO-X Adaptive Optics","description":"\u003cp\u003eThe next-generation of adaptive optics for our SBIG large-format cameras. Requires a StarChaser SC-3 guide camera (or an older self-guiding system).\u003c\/p\u003e\n\u003cp\u003eThe SBIG AO-X is a large aperture AO designed to be compatible with all large format SBIG cameras.  It requires an off-axis guide camera behind the AO; typically the  StarChaser SC-3 is used.\u003c\/p\u003e\n\u003cp\u003eThe AO-X is compatible with the Aluma AC4040, Aluma AC2020, and Aluma AC455 cameras, when used with a StarChaser SC-3.\u003c\/p\u003e\n\u003cp\u003eAO-X is also compatible with older STX-16803, STXL-16200, STXL-11000, and STXL-6303 cameras.  Guiding can be performed via a StarChaser SC-3, or through older guide systems including STX Guider, FW8G-STXL self-guided filter wheels, the built-in guide sensor on some STX cameras, or a Remote Guide Head with an off-axis guider behind the AO-X.\u003c\/p\u003e\n\u003ch3\u003eAO Results:\u003c\/h3\u003e\n\u003cp\u003eThe images below are actual star images showing the effect of image wander corrected at 1 Hz and 10 Hz:\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"size-full wp-image-1834 aligncenter\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/ao_mov_1hz_ddbbbef8-60d0-47d6-9fed-407638e78225.gif?v=1766567136\" alt=\"ao_mov_1hz\" width=\"200\" height=\"200\"\u003e1 Hz Corrections\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"size-full wp-image-1825 aligncenter\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/ao_mov_10hz_6d5dfd6f-38b5-4b0b-ab5a-11ef024d19a2.gif?v=1766567138\" alt=\"ao_mov_10hz\" width=\"200\" height=\"200\"\u003e10 Hz Corrections\u003c\/p\u003e\n\u003cp\u003eAnd the resulting size of the star image in a long exposure:\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"aligncenter\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/aox-1hz-corrected-250x250_b53639db-bda2-4d85-bcbd-ccde075212ee.png?v=1766567139\" alt=\"aox-1hz-corrected\"\u003e1 Hz Corrections\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"aligncenter\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/aox-10hz-corrected-250x250_c2a77add-3fbd-4844-aa24-44d11eeb377d.png?v=1766567141\" alt=\"aox-10hz-corrected\"\u003e10 Hz Corrections\u003c\/p\u003e\n\u003cp\u003eOther data gathered by Brad Wallis of JPL (Brad Wallis and Benoit Schillings developed the prototype for the original AO-7) show the the effect of rapid corrections on poor seeing.  At 1 Hz the larger, slower component is reduced, but the amplitude of the jitter remains about the same:\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"alignnone wp-image-1832 size-full\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/ao_1hz_e97ca480-f413-476e-90b5-145507e40cf8.gif?v=1766567142\" alt=\"ao_1hz\" width=\"959\" height=\"719\"\u003e\u003c\/p\u003e\n\u003cp\u003eHowever, at a 5Hz correction rate, the faster jitter is reduced:\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"alignnone wp-image-1831 size-full\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/ao_5hz_84ad5500-859a-4706-8b13-a1369dbc8508.gif?v=1766567144\" alt=\"ao_5hz\" width=\"959\" height=\"719\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnd at a 10 Hz correction rate, significant improvement is seen:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"alignnone wp-image-1830 size-full\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/ao_10hz_7eb10039-4bb6-46d7-b2cd-d4049eb6c3fe.gif?v=1766567145\" alt=\"ao_10hz\" width=\"959\" height=\"719\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe improvement in stellar profiles can also be seen at corrections above 1 Hz.  First by looking at the non-AO guided image:\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"alignnone wp-image-1829 size-full\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/aox_img2_d14bdde3-1958-4d1f-beff-7a18055d4eda.jpg?v=1766567147\" sizes=\"(max-width: 687px) 100vw, 687px\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/aox_img2_d14bdde3-1958-4d1f-beff-7a18055d4eda.jpg?v=1766567147 687w, https:\/\/diffractionlimited.com\/wp-content\/uploads\/2016\/11\/aox_img2-600x594.jpg 600w\" alt=\"aox_img2\" width=\"687\" height=\"680\"\u003e\u003c\/p\u003e\n\u003cp\u003eAnd comparing the non-AO guided image to the AO guided image there is again significant improvement in the FWHM of the star profile:\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"alignnone wp-image-1828 size-full\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/ao_img2_4413ca6a-d51e-42ab-8564-bbed06d15171.jpg?v=1766567149\" sizes=\"(max-width: 720px) 100vw, 720px\" srcset=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/ao_img2_4413ca6a-d51e-42ab-8564-bbed06d15171.jpg?v=1766567149 720w, https:\/\/diffractionlimited.com\/wp-content\/uploads\/2016\/11\/ao_img2-600x473.jpg 600w, https:\/\/diffractionlimited.com\/wp-content\/uploads\/2016\/11\/ao_img2-700x552.jpg 700w\" alt=\"ao_img2\" width=\"720\" height=\"568\"\u003e\u003c\/p\u003e\n\u003cp\u003eTelescope mounts cannot correct faster than about once per second.  The 10Hz rate of the AO-X will clearly result in improved resolution under the right conditions.\u003c\/p\u003e\n\u003ch2 class=\"resp-accordion resp-tab-active\" role=\"tab\" aria-controls=\"tab_item-1\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003eSPECIFICATIONS:\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv id=\"tab-additional_information\" class=\"tab-content resp-tab-content resp-tab-content-active\" aria-labelledby=\"tab_item-1\"\u003e\n\u003ctable class=\"woocommerce-product-attributes shop_attributes table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"woocommerce-product-attributes-item woocommerce-product-attributes-item--attribute_pa_power\"\u003e\n\u003cth class=\"woocommerce-product-attributes-item__label\"\u003ePower\u003c\/th\u003e\n\u003ctd class=\"woocommerce-product-attributes-item__value\"\u003e\n\u003cp\u003eSupplied through Camera’s I2C Port\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"woocommerce-product-attributes-item woocommerce-product-attributes-item--attribute_pa_os-compatibility\"\u003e\n\u003cth class=\"woocommerce-product-attributes-item__label\"\u003eOS Compatibility\u003c\/th\u003e\n\u003ctd class=\"woocommerce-product-attributes-item__value\"\u003e\n\u003cp\u003eWindows 32 and 64 bit OS, Mac\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"woocommerce-product-attributes-item woocommerce-product-attributes-item--attribute_pa_computer-interface\"\u003e\n\u003cth class=\"woocommerce-product-attributes-item__label\"\u003eComputer Interface\u003c\/th\u003e\n\u003ctd class=\"woocommerce-product-attributes-item__value\"\u003e\n\u003cp\u003eI2C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"woocommerce-product-attributes-item woocommerce-product-attributes-item--attribute_pa_dimensions\"\u003e\n\u003cth class=\"woocommerce-product-attributes-item__label\"\u003eDimensions\u003c\/th\u003e\n\u003ctd class=\"woocommerce-product-attributes-item__value\"\u003e\n\u003cp\u003e6 x 7 x 1.2 in.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"woocommerce-product-attributes-item woocommerce-product-attributes-item--attribute_pa_weight\"\u003e\n\u003cth class=\"woocommerce-product-attributes-item__label\"\u003eWeight\u003c\/th\u003e\n\u003ctd class=\"woocommerce-product-attributes-item__value\"\u003e\n\u003cp\u003e2.2 lbs (1 kg)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Diffraction Limited","offers":[{"title":"Default Title","offer_id":44013933101167,"sku":"AO-X","price":3103.65,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/0049\/6239\/files\/AOX-new-e1477602579549-600x627__41572.jpg?v=1766567151"}],"url":"https:\/\/ontariotelescope.com\/collections\/dl-adaptive-optics.oembed","provider":"Ontario Telescope and Accessories","version":"1.0","type":"link"}